[ aws . iotsitewise ]
Updates a gateway capability configuration or defines a new capability configuration. Each gateway capability defines data sources for a gateway. A capability configuration can contain multiple data source configurations. If you define OPC-UA sources for a gateway in the AWS IoT SiteWise console, all of your OPC-UA sources are stored in one capability configuration. To list all capability configurations for a gateway, use DescribeGateway .
See also: AWS API Documentation
See ‘aws help’ for descriptions of global parameters.
update-gateway-capability-configuration
--gateway-id <value>
--capability-namespace <value>
--capability-configuration <value>
[--cli-input-json | --cli-input-yaml]
[--generate-cli-skeleton <value>]
[--cli-auto-prompt <value>]
--gateway-id
(string)
The ID of the gateway to be updated.
--capability-namespace
(string)
The namespace of the gateway capability configuration to be updated. For example, if you configure OPC-UA sources from the AWS IoT SiteWise console, your OPC-UA capability configuration has the namespace
iotsitewise:opcuacollector:version
, whereversion
is a number such as1
.
--capability-configuration
(string)
The JSON document that defines the configuration for the gateway capability. For more information, see Configuring data sources (CLI) in the AWS IoT SiteWise User Guide .
--cli-input-json
| --cli-input-yaml
(string)
Reads arguments from the JSON string provided. The JSON string follows the format provided by --generate-cli-skeleton
. If other arguments are provided on the command line, those values will override the JSON-provided values. It is not possible to pass arbitrary binary values using a JSON-provided value as the string will be taken literally. This may not be specified along with --cli-input-yaml
.
--generate-cli-skeleton
(string)
Prints a JSON skeleton to standard output without sending an API request. If provided with no value or the value input
, prints a sample input JSON that can be used as an argument for --cli-input-json
. Similarly, if provided yaml-input
it will print a sample input YAML that can be used with --cli-input-yaml
. If provided with the value output
, it validates the command inputs and returns a sample output JSON for that command.
--cli-auto-prompt
(boolean)
Automatically prompt for CLI input parameters.
See ‘aws help’ for descriptions of global parameters.
To update a gateway capability
The following update-gateway-capability-configuration
example configures an OPC-UA source with the following properties:
Trusts any certificate.
Uses the Basic256 algorithm to secure messages.
Uses the SignAndEncrypt mode to secure connections.
Uses authentication credentials stored in an AWS Secrets Manager secret.
aws iotsitewise update-gateway-capability-configuration \
--gateway-id a1b2c3d4-5678-90ab-cdef-1a1a1EXAMPLE \
--capability-namespace "iotsitewise:opcuacollector:1" \
--capability-configuration file://opc-ua-capability-configuration.json
Contents of opc-ua-capability-configuration.json
:
{
"sources": [
{
"name": "Wind Farm #1",
"endpoint": {
"certificateTrust": {
"type": "TrustAny"
},
"endpointUri": "opc.tcp://203.0.113.0:49320",
"securityPolicy": "BASIC256",
"messageSecurityMode": "SIGN_AND_ENCRYPT",
"identityProvider": {
"type": "Username",
"usernameSecretArn": "arn:aws:secretsmanager:us-west-2:123456789012:secret:greengrass-windfarm1-auth-1ABCDE"
},
"nodeFilterRules": []
},
"measurementDataStreamPrefix": ""
}
]
}
Output:
{
"capabilityNamespace": "iotsitewise:opcuacollector:1",
"capabilitySyncStatus": "OUT_OF_SYNC"
}
For more information, see Configuring data sources in the AWS IoT SiteWise User Guide.
capabilityNamespace -> (string)
The namespace of the gateway capability.
capabilitySyncStatus -> (string)
The synchronization status of the capability configuration. The sync status can be one of the following:
IN_SYNC
– The gateway is running the capability configuration.
OUT_OF_SYNC
– The gateway hasn’t received the capability configuration.
SYNC_FAILED
– The gateway rejected the capability configuration.After you update a capability configuration, its sync status is